JM Type ODP Pump Motors - NEMA Premium Efficiency

DATA SHEETS AND DRAWINGS

Standard features
  • Three phase, 2 & 4 pole, 60Hz
  • Voltage: 230/460V, 460V or 575V
  • Squirrel cage rotor / Aluminum die cast
  • Class “F” insulation
  • Temperature rise: Class “B” (80ºC)
  • 104°F (40ºC) ambient temperature
  • Continuous Duty (S1)
  • NEMA dimensions
  • Open drip proof
  • Service Factor: 1.15
  • Stainless steel nameplate - 254JM and up
  • 1045 carbon steel shaft
  • F1 mount (with cast iron ‘C’ Flange)
  • NPT threaded terminal box conduit hole
  • Paint: Enamel alkyd resin base
  • Color: RAL 5007 (Blue)
  • Weg paint plan: 201A
  • Drip cover for all vertical motors
Frame Specific Features For Frame 143/5 JM
  • Welded steel plate frames (welded feet)
  • Cast iron endshields fixed with through bolt construction
  • “ZZ” bearings (double shielded)
  • Degree of protection: IP21
For Frame 182 JM up to 215 JM
  • Welded steel plate frames (welded feet)
  • Aluminum endshields and Terminal box
  • Cooling system with finned rotor
  • “ZZ” bearings (double shielded)
  • Degree of protection: IP21
For Frame 254 JM up to 445 JM
  • Cast iron frames
  • Cast iron endshields and terminal box
  • Cooling system with finned rotor
  • Regreasable bearings system (frame 254JM and up)
  • Degree of protection: IP23
Optional Features
  • Special voltages
  • Cable glands
  • Thermistors, Thermostats or RTD”s (PT100) - For frames 182JM and up
  • IEC metric frames (on request) - For frames 254JM up to 365JM
Fire Pump Duty Motor also certified for fire pump application with SF 1.15 Suitable for Inverter Duty Applications Typical Applications Specially developed line for industrial and commercial pumping applications.
  • Water pumping
  • Process
  • Transfer and circulating pumps
  • Other